Last data update: May 06, 2024. (Total: 46732 publications since 2009)
Records 1-2 (of 2 Records) |
Query Trace: Gatcombe M[original query] |
---|
Simultaneous measurement of total estradiol and testosterone in human serum by isotope dilution liquid chromatography tandem mass spectrometry
Zhou H , Wang Y , Gatcombe M , Farris J , Botelho JC , Caudill SP , Vesper HW . Anal Bioanal Chem 2017 409 (25) 5943-5954 Reliable measurement of total testosterone and estradiol is critical for their use as biomarkers of hormone-related disorders in patient care and translational research. We developed and validated a mass spectrometry method to simultaneously quantify these analytes in human serum without chemical derivatization. Serum is equilibrated with isotopic internal standards and treated with acidic buffer to release hormones from their binding proteins. Lipids are isolated and polar impurities are removed by two serial liquid-liquid extraction steps. Total testosterone and estradiol are measured using liquid chromatography tandem mass spectrometry (LC-MS/MS) in combination of positive and negative electrospray ionization modes. The method shows broad analytical measurement range for both testosterone 0.03-48.5 nM (0.75-1400 ng/dL) and estradiol 11.0-5138 pM (2.99-1400 pg/mL) and excellent agreement with certified reference materials (mean bias less than 2.1% to SRM 971, BCR 576, 577, and 578) and a high order reference method (mean bias 1.25% for testosterone and -0.84% for estradiol). The high accuracy of the method was monitored and certified by CDC Hormone Standardization (HoSt) Program for 2 years with mean bias -0.7% (95% CI -1.6% to 0.2%) for testosterone and 0.1% (95% CI -2.2% to 2.3%) for estradiol. The method precision over a 2-year period for quality control pools at low, medium, and high concentrations was 2.7-2.9% for testosterone and 3.3-5.3% for estradiol. With the consistently excellent accuracy and precision, this method is readily applicable for high-throughput clinical and epidemiological studies. |
Evaluation of a molecular beacon real-time PCR assay for detection of Baylisascaris procyonis in different soil types and water samples
Gatcombe RR , Jothikumar N , Dangoudoubiyam S , Kazacos KR , Hill VR . Parasitol Res 2009 106 (2) 499-504 Baylisascaris procyonis is a helminth parasite commonly found in North American raccoons (Procyon lotor) that is a cause of clinical neural, ocular, and visceral larva migrans in humans when infective eggs are ingested. Rapid detection of B. procyonis eggs in contaminated soil and water would assist public health analysts in evaluating risks associated with public exposure to areas of known raccoon activity. In this study, a molecular beacon probe-based real-time polymerase chain reaction (PCR) assay was developed to enable rapid and specific detection of eggs of Baylisascaris spp. The molecular beacon assay targeted the cytochrome oxidase subunit 2 (cox-2) gene of B. procyonis. To determine method sensitivity, experiments testing various egg levels (250, 25, and five eggs) were performed by seeding into 0.5-g soil samples or 0.5-mL water samples. Different soil sample types were extracted using a commercial nucleic acid extraction kit. Specificity testing using previously characterized helminth tissue specimens indicated that the assay was specific to Baylisascaris spp. Little real-time PCR inhibition was observed for most of the soil and water samples. A seed level of 250 eggs was detected for all soil types, and two seed levels (25 and five eggs) were detected for surface water samples. These results demonstrate that the reported real-time PCR assay was effective for the sensitive detection of B. procyonis in a wide range of soil types, and should be a useful tool for investigations of soil or water potentially contaminated with eggs of this parasite. |
- Page last reviewed:Feb 1, 2024
- Page last updated:May 06, 2024
- Content source:
- Powered by CDC PHGKB Infrastructure